NOTES - CONTINUED:
2.
OIL CAN POINTS. Each 10 hours lubricate all control level pivots, feedgate pivots, and all exposed
adjusting threads with OE/HDO.
3.
TRANSPORT WHEEL BEARINGS. Each 500 hours, remove wheels, clean and inspect all parts, replace
damaged or worn parts. Repack bearings and assemble.
4.
AGITATOR ROLLER BEARINGS. When agitator is in place, check roller bearing grease fittings for
damage.
5.
GEAR BOX. Check level each 50 hours. Change gear lubricant only when required by maintenance
repair action, contamination by water, or other foreign material. After refill, operate for five minutes, check for
leaks and bring oil level to level plug opening. Drain when lubricant is warm
6.
LUBRICANTS. The following is a list of lubricants with military symbols and applicable specification
numbers.
OE/HDO
MIL-L-2104
GO
MIL-L-2105
GAA
MIL-G-10924
OEA
MIL-L-46167
CW
VV-L-751
(SD), Type II
P-D-680
Copy of this Lubrication Order will remain with the equipment at all times, instructions contained herein are
mandatory.
By order of the Secretary of the Army:
JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
OFFICIAL:
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25B, Operator and Organizational maintenance
requirements for Aggregate Spreaders.
TA 2 19666
LO 5-3895-330-12