TM 5-3895-367-14&P
LUBRICATION INSTRUCTIONS
SPREADER, AGGREGATE: TOWED; 8 FT SPREAD
FF-8 (NSN 3895-01-329-5096)
Hard time intervals and related man-hour times are
based on normal operation. The man-hour time
specified is the time you need to do all services pre-
scribed for a particular interval. Decrease the intervals if
your lubricants are contaminated, or if you are operating
equipment under adverse conditions, including longer-
than-usual operating hours. The intervals may be
extended during periods of low activity. If extended,
adequate preservation precautions must be taken.
Dotted leader lines indicate lubrication is required on
both sides of the equipment.
WARNING
Dry cleaning solvent P-D-680 is toxic
and flammable. Wear protective
goggles, face mask, and gloves and
use in a well ventilated area. Avoid
contact with skin, eyes, and clothes
and do not breath vapors. Do not use
near open flame or excessive heat.
The flash point for Type I solvent is
100 degrees F (38 degrees C). The
flash point for Type II solvent is 140
degrees F (60 degrees C). If you be-
come dizzy while using cleaning
solvent, get fresh air immediately and
get medical aid. If contact with eyes
is made, wash your eyes with water
and get medical aid immediately.
Clean all fittings and area around lubrication points with
dry cleaning solvent (Item 11, Appendix E) or equivalent
before lubricating equipment. After lubrication, wipe off
excess oil or grease to prevent accumulation of foreign
matter.
The lowest level of maintenance authorized to lubricate a
point is indicated in parentheses by use of the following:
(C) Operator/Crew; or (O) Organizational Maintenance.
3-3