TM 5-3895-367-14&P
5-4. AGITATOR REPAIR (CONT).
(3)
Remove nut (73), lockwasher (74), flatwasher
(75), and square neck bolt (76) securing
center bearing (21) to bearing hanger (29).
Discard lockwasher.
(4)
Remove nut (77), lockwasher (78), flatwasher
(79), and screw (80) securing center bearing
(21) to bearing hanger (29). Remove center
bearing from bearing hanger. Discard
lockwasher.
(5)
Remove square neck bolt (24) from bearing
hanger (29).
(6)
Remove lubrication fitting (81) from center
bearing (21).
(7)
Loosen setscrew (82) and remove collar (83)
from left-hand pipe end pin (84).
(8)
Remove locknut (85) and screw (86) securing
left-hand pipe end pin (84) to left-hand side of
agitator pipe assembly (8). Remove end pin
from agitator pipe assembly. Discard locknut.
(9)
Loosen setscrew (87) and remove collar (88)
from right-hand pipe end pin (13).
(10)
Remove locknut (89) and screw (90) securing
right-hand pipe end pin (13) to right side of
agitator pipe assembly (20). Remove end pin
from agitator pipe assembly. Discard locknut.
c.
Cleaning and Inspection.
WARNING
Dry cleaning solvent P-D-680 is toxic and
flammable. Wear protective goggles, face mask,
and gloves and use in a well ventilated area.
Avoid contact with skin, eyes, and clothes and
do not breath vapors. Do not use near open
flame or excessive heat. The flash point for Type
I solvent is 100 degrees F (38 degrees C). The
flash point for Type II solvent is 140 degrees F
(60 degrees C). If you become dizzy while using
cleaning solvent, get fresh air immediately and
get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid
immediately.
(1)
Clean all parts with dry cleaning solvent and dry
thoroughly.
(2)
Inspect all parts for cracks, breaks, or other
damage. Replace all damaged parts.
5-18