TM 5-3895-367-14&P
4-23. TRANSPORT TONGUE AND MOUNTING COMPONENTS REPLACEMENT (CONT)
(3)
Remove cotter pin (9) and pin (10)
securing each safety chain (11) to angle
(12). Remove safety chains. Discard
cotter pins.
(4)
Remove four nuts (13), lockwashers (14),
and screws (15). Remove angle (12) from
spreader. Discard lockwashers.
(5)
Remove four nuts (16), lockwashers (17),
and screws (18). Remove frame section
(19) from spreader. Discard lockwashers.
b.
Disassembly.
(1)
Remove cotter pin (20) and pin (21)
securing clevises (22) to each end of
safety chain (11). Remove clevises.
Discard cotter pins.
(2)
Remove hair pin (23) and pin (24) from
front clevises (22).
(3)
Repeat steps (1) and (2) for remaining
safety chain.
c.
Cleaning and Inspection.
WARNING
Dry cleaning solvent P-D-680 is toxic
and
flammable.
Wear
protective
goggles, face mask, and gloves and use
in a well ventilated area. Avoid contact
with skin, eyes, and clothes and do not
breath vapors. Do not use near open
flame or excessive heat. The flash point
for Type I solvent is 100 degrees F (38
degrees C). The flash point for Type II
solvent is 140 degrees F (60 degrees
C). If you become dizzy while using
cleaning
solvent,
get
fresh
air
immediately and get medical aid. If
contact with eyes is made, wash your
eyes with water and get medical aid
immediately.
(1)
Clean all parts with dry cleaning solvent
and dry thoroughly.
(2)
Inspect all parts for cracks, breaks, or
damage. Replace all damaged parts.
4-42